Eurotherm 2132 Controller Manual Average ratng: 7,8/10 1157votes

A universal input enables selection of nine internally stored thermocouple types and the PT100 resistance thermometer. Linear inputs can be scaled to the desired display range. Two relay outputs are configurable for alarms. Nile Valley Contributions To Civilization Ebook. Three internal alarm setpoints are provided- configurable as high, low or deviation.

Eurotherm 2132 Controller Manual

3216, 3208, 3204. Eurotherm Limited pursues a policy of continuous development and product. 11.1.3.1 Motorised Valve Control in Manual mode. MC11 – 1.03 Operating Instructions Temperature Controller Eurotherm 2216 Including 2132 or 2116 Overtemperature Controller Instructions See also the main manual for. 2132 and 2116 PID Temperature Controllers. Thank you for choosing the 2132 or 2116 Temperature Controller. Supplied in 1/32 and 1/16. -100% = max cooling, 100.0% = max heating. Only appears when setpoint rate limit enabled. Eurotherm 2132 Temperature Controller 1/32 DIN. Eurotherm 2132 Temperature Controller Eurotherm. You can download the 2132 manual on our.

Alarms can be 'blocked' on start-up to prevent unnecessary operator alerts. 2100 Series Controller The compact Eurotherm, 1/32 DIN panel size, 2132 temperature controller uses advanced PID algorithms to give stable temperature control. Specialist knowledge or training is not needed to optimize the control performance, because Self-tuning is included. • Simple operation • Three internal alarms • Up to two relay outputs • One logic input or output • Reliable performance and accuracy • Internal timer - a 5 mode timer suitable for simple time based profiling applications • Universal input - 9 thermocouple types, PT100, DC linear and a downloadable custom curve Universal input/two outputs Linear inputs can be scaled to the desired display range. A universal input enables selection of nine internally stored thermocouple types and the PT100 resistance thermometer. Other input linearizations may be factory downloaded.

Two outputs are configurable for heating, cooling or alarms. Operator interface The operator interface can be customized to present only those parameters that an operator needs to see and adjust, while other parameters are locked away under password protection.

Internal alarm set points Alarms can be 'blocked' on start-up to prevent unnecessary operator alerts. Three internal alarm set points are provided - configurable as high, low or deviation alarms. Heater failure can be detected using PDSIO when the controller is used with a TE10S Solid State Relay - this negates the need to use extra components such as current transformers. Internal timer A five mode timer is provided for simple, time-based profiling applications.

This video tutorial will demonstrate the basic OPERATIONS LEVEL setup of a Eurotherm 2132/2116 controller. The 2132/2116 controller is a fixed hardware configuration instrument. What this means is that it comes standard with a logic output on terminals 1A and 1B and a relay output on terminals AA and AB. For the purposes of this demonstration we will consider the 2132/2116 to be set up as a heat / cool controller with the logic output setup as the heating output and the relay output setup as the cooling output and the process input will be a Type K Thermocouple setup in degrees F. We will be using the four keys located across the bottom of the controller to navigate / change the parameters of the 2132/2116 controller. The left most key is the PAGE key.